 |
Installation
&
Troubleshooting
|
Installation Instructions
The Window Master program has three main components. Paradox full version
or Paradox Run Time is required, the application itself, which resides on the
local station, and the network folders where all the data is stored. To install
Window Master:
- Create
a folder on a network drive called “Network”. This folder should have full
access rights to Window Master users. Extract the network files here.
- Create
a folder on the same network drive called “WMUpdate”. This is where updates are
distributed from. When you post updates from your Administrator station, this is
where the update is stored.
- Create
a folder on the same network drive called “Pdoxusrs”. This is where the Network
Control files will be.
- Create
a folder on the c: drive of each local station called c:\Paradoxl. Paradoxl
stands for Paradox Local and is where the application is kept. Extract the
application files here.
- Install Paradox or Paradox Runtime.
- Run the
BDE administrator from the control panel.
- Set the NET DIR to the path on the network control drive and folder you created.

- Set the local share to True.
-
Close the BDE Administrator and be sure to respond Yes to “Save all edits to
BDE Administrator”.

-
Launch Paradox or Paradox Runtime.

-
Select [File][Working Directory] and set the working directory to
c:\paradoxl.
-
Select [Tools][Alias Manager] and create a “net” alias pointing to your network folder
on the server (\\ServerName\ShareName\Network).

-
Select
[Tools][Alias Manager] and create an “updte” alias pointing to your WMUpdate
folder on the server. (\\ServerName\ShareName\WMUpdate).

-
Create
a shortcut to “WMStart.ssl” in the c:\paradoxl folder. This is the shortcut to
start the application.
Trouble Shooting
If problems are encountered it is usually a problem with the network control
within Paradox. Paradox controls multiple applications on a network with .lck
and .net files. These files will either have the name paradox or pdoxusrs. First
close paradox on the station experiencing the problem and delete all paradox.lck
and pdoxusrs.lck files as well as paradox.net and pdoxusrs.net. If the problem
still persists, close all sessions of paradox on all stations. Delete all .lck
and .net files on each station.
Then delete the .lck and .net files from the network folders on the server as
well.
Caution: Other
programs use .lck and .net files to. Only delete files with the name Paradox or
Pdoxusrs.
There is a tool to delete these files in the c:\Paradoxl folder. Create a
shortcut to c:\paradoxl\dlcknet.exe and execute it when you want to delete .lck
and .net files. Note:
Paradox must always be shut down before executing this tool.
For all other problems, please call Lyndon. (403) 291-3960
|