Installation
&
Troubleshooting
|
Installation Instructions
The Window Master program has three main components. Paradox full
version or Paradox Run Time is required, the application itself, which
resides on the local station, and the network folders where all the data is
stored. To install Window Master:
- Create
a folder on a network drive called “Network”. This folder should
have full access rights to Window Master users. Extract the network
files here.
- Create
a folder on the same network drive called “WMUpdate”. This is where
updates are distributed from. When you post updates from your
Administrator station, this is where the update is stored.
- Create
a folder on the same network drive called “Pdoxusrs”. This is where
the Network Control files will be.
- Create
a folder on the c: drive of each local station called c:\Paradoxl.
Paradoxl stands for Paradox Local and is where the application is kept.
Extract the application files here.
- Install
Paradox or Paradox Runtime.
- Run
the BDE administrator from the control panel.
- Set
the NET DIR to the path on the network control drive and folder you
created.

- Set
the local share to True.

9. Close the BDE Administrator and be sure to respond Yes
to “Save all edits to BDE Administrator”.
- Launch
Paradox or Paradox Runtime.
- Select
[File][Working Directory] and set the working directory to c:\paradoxl.
- Select
[Tools][Alias Manager] and create a “net” alias pointing to your
network folder on the server (\\ServerName\ShareName\Network).

- Select
[Tools][Alias Manager] and create an “updte” alias pointing to your
WMUpdate folder on the server. (\\ServerName\ShareName\WMUpdate).

- Create
a shortcut to “WMStart.ssl” in the c:\paradoxl folder. This is the
shortcut to start the application.
Trouble Shooting
If problems are encountered
it is usually a problem with the network control within Paradox. Paradox
controls multiple applications on a network with .lck and .net files. These
files will either have the name paradox or pdoxusrs. First close paradox on
the station experiencing the problem and delete all paradox.lck and
pdoxusrs.lck files as well as paradox.net and pdoxusrs.net. If the problem
still persists, close all sessions of paradox on all stations. Delete all .lck
and .net files on each station. Then
delete the .lck and .net files from the network folders on the server as
well.
Caution: Other programs use .lck and .net
files to. Only delete files with the name Paradox or Pdoxusrs.
There is a tool to delete
these files in the c:\Paradoxl folder. Create a shortcut to c:\paradoxl\dlcknet.exe
and execute it when you want to delete .lck and .net files. Note:
Paradox must always be shut down before executing this tool.
For all other problems,
please call Lyndon. (403) 291-3960
|